Fault code P2BAA – NOx exceedence – low reagent consumption

Fault code P2BAA is called “NOx Exceedence – Low Reagent Consumption” but in different programs it may be called differently. This fault designation applies to all vehicles equipped with OBD-II.

Technical description and explained code P2BAA

The OBD-II P2BAA error code is a general fault defined as “nitrogen oxides (NOx) exceeded due to low flow rate of reagents”. It is set when the Powertrain Control Module (PCM) detects that the level of nitrogen oxides (NOx) in the exhaust gases exceeds the maximum allowable threshold. Exceeding occurs as a result of disabling the exhaust gas recirculation system.

Fault code P2BAA – NOx exceedence – low reagent consumption

Diesel Exhaust Fluid (DPF) helps convert harmful exhaust particles into harmless ones. In order to burn these particles, the temperature of the exhaust system must be increased.

DEF liquid is injected into the exhaust gas stream to bring it up to optimal temperature. The exhaust system then converts the harmful nitrous oxide compounds into nitrogen, carbon dioxide and water.

The reducing agent pump transfers the diesel exhaust fluid (DPF) from the tank to the injector. And if the NOx sensor is not working according to the Powertrain Control Module (PCM), the code P2BAA may be stored.

This code is informational and is set only to alert the driver that an excess of nitrogen oxides (NOx) has been detected. The reason for the excess is indicated. In this case, a low flow of reagents has been detected.

Because of the low flow of chemicals, an excessive amount of NOx is sure to be generated. Therefore, the PCM will set the P2BAA code and turn on the warning lamp as a warning that the nitrogen oxides (NOx) level has been exceeded.

Symptoms of vehicle malfunctions

The main signal that an error P2BAA has occurred is the Malfunction Indicator Lamp (MIL) is also known as the CheckEngine Light.

It can also be warning signs such as:

  1. Check engine control lamp on the control panel will light up (the code will be recorded in the memory as a malfunction).
  2. Black smoke from the exhaust pipe.
  3. Reduced engine power.
  4. Increased fuel consumption.

The severity of the stored code P2BAA depends on what related codes are present. This error itself has no symptoms, but is only a notification of excessive nitrogen oxides (NOx).

Factors that can cause this error code

The error code P2BAA can mean that one or more of the following problems have occurred:

  • DPF fluid in the reservoir has run out.
  • Incorrect DPF or NOx recovery fluid.
  • Ineffective DPF recovery or NOx capture due to driving habits.
  • Defective catalytic converter.
  • Faulty DPF, NOx pickup, or oxygen sensor O₂.
  • Sometimes the cause is a defective PCM module or its programming error.

How to fix or reset OBD-2 code P2BAA

Some suggested steps for troubleshooting and fix the error code P2BAA:

  1. Read all stored data and error codes with an OBD-II scan tool. To find out when and under what circumstances the error P2BAA appeared.
  2. Clear the error codes from the computer memory and test drive the vehicle to find out if the fault appears again.
  3. Note which DPF or NOx recovery fluid is being used.
  4. Test the oxygen O₂ sensors as well as the catalytic converter.
  5. If no problems are found anywhere, check and, if necessary, replace the power train control module (PCM).

Diagnose and repair of problems

The first thing to do is to check the maintenance bulletins (TSB) for your particular vehicle. Your problem may be a known problem with a known fix issued by the manufacturer. This can save you time and money during diagnosis.

Next, make sure there is enough and the correct type of DPF regeneration or NOx trapping fluid present in your vehicle. This code is a direct result of a stored DPF, NOx catcher or O₂ sensor code.

Therefore, you must first diagnose and correct any other codes that are present. Correcting a DPF or NOx trap regeneration fluid problem can eliminate the conditions that cause these types of codes to persist.

Certain driving habits can also affect DPF and NOx trap regeneration. Short trips and trips that do not require efficient engine loading may not provide sufficient DPF or NOx trap regeneration.

Use the appropriate diagnostic information for the codes that accompany the P2BAA error, diagnose and repair them first. After that, this problem should also disappear.

Trying to correct this error without correcting the other stored codes may be a waste of time.

On which vehicles does this problem occur most frequently

Fault code P2BAA can occur on different vehicles but there are statistics on which brands this occurs most often. Here is a list of some of them:

  • Isuzu
  • Mercedes-Benz (Sprinter)
  • Opel
  • Renault

Fault code P2BAA can sometimes be found with other errors. The most common are the following: P2BA7, P2BA8, P2BA9, P2BAB, P2BAC, P2BAD, P2BAE.

Video

Rate article
AutoNevod | Technical description of OBD-2 car faults and their solution
Add a comment